F-2200 Series Vortex Flow Meter Installation and Operation Guide • Revised 12/08
12
The diagrams shown below illustrate the correct meter orientation for vertical and horizontal pipe.
Nominal Meter Size
(in.)
Meter Body
Diameter (in.)
Maximum Pipe ID
Difference (in.)
1” 1.05 0.016
1 1/2” 1.61 0.016
2” 2.07 0.024
3” 3.07 0.024
4” 4.03 0.024
6” 6.07 0.031
8” 7.98 0.039
Ensure that the bore of the locating pipes are smooth and without deposits,
scaling, or welding beads.
3.1.2 Maximum Allowable Difference Between Inside Diameter Of Meter Body
And The Connecting Pipe
The table below provides the maximum allowable difference between the diameter of
the ow meter body and the connecting pipe.